Fonix FP35 hearing aid test box

I cannot level my FP35, any suggestions?
Yes.
It could be caused by a faulty chamber microphone, however there is also a possible 'user generated cause'. In the default settings {Menu from first screen} there is an option to select a 'reference microphone'. Selecting 'yes', by mistake, on an FP35 which does not have a refeence microphone (most do not) will result in a levelling error. See example default menu screen below- the ref mic choice is at the top reight.

A quick explanation of the settings are:
Print label = off - will stop printing the dotted lines on the right side of a printed which most people do not write on.
Printer = internal - you can use an external printer
Screen mode = light - that's dark writing on a light background, you can select to have a dark background with light writing.
Screen saver = 10 - that's the time before the screen goes dark.
Baudrate - only relevant when connected to a computer.
Aid Group = Adpative - Adaptive is correct for digital aids with WDRC, you can also choose AGC and Linear. This field affects the settling time before recording readings (I think!).
Ref mic = off - few FP35 test boxes have a referemnce microphone.
Distortion = Total - this is the usual choice. A choice of 'off' could be the reason you never see distortion results for a pure tone sweep!
Noise reduction (tone - pure tone) = off, 4x - when noise reduction is turned on eg 4X the test box repeats the measurments and takes an average.
Noise reduction (comp - composite and digital composite/speech) = 4X - as above
Please note that noise reduction is a useful feature but does not really allow you to use the test box in a noisy room. We would advise against using a noise reduction greater than 4X, you can get misleading results.
To store changed settings you need to select the 'Store menu' button (bottom right) and follow instructions.
page search ref FAQFONIX03